TBM4M

TBM4M

TBM4M 4-channel transducer amplifier


  • Overview
  • Specifications
  • Accessories
  • Citations
  • Related Products

Overview

TBM4M 4-Channel Transducer Amplifier

There are 1 images available to view - click to enlarge and scroll through the product gallery.

TBM4M Instruction Manual
/ Download as PDF

Amplify output voltage signals

  • Use with many different types of resistive based transducers
  • WPI resistive force transducers plug in directly
  • Supports full resistive bridge or single ended operation
  • Output offset control
  • Four gain ranges from 1–1000 ×
  • Provides “excitation” voltage for resistive bridge transducers

Benefits

  • Provided with blank connectors to interface with any resistive bridge transducer
  • Bridge balance LEDs provide visual cue that unloaded transducers are at zero output state

Applications

  • Amplify signals from resistive strain gages and other resistive bridge configured transducers

TBM4M 4-Channel Transducer Amplifier

Transbridge (SYS-TBM4M) is a four-channel analogue transducer manifold, specifically designed to amplify output voltage signals from pressure, force, displacement, and temperature transducers as well as a wide variety of other signal sources. Analog output signals are available from each channel for input to a data acquisition system for digital signal processing in a computer. Each channel contains a regulated 10 V power supply (+5 and -5 V with respect to signal ground) to provide DC power to transducers, and a precision differential amplifier with selectable voltage amplification and variable position adjustment control.

Each channel contains a regulated 10-volt power supply (+5 and -5 volts with respect to signal ground) to provide DC power to transducers, and a precision differential amplifier with selectable voltage amplification and variable position adjustment control.

Transducers

Transducers can be connected to Transbridge via any of the 8-pin connectors on the front panel. Four spare 8-pin DIN plugs are provided with each instrument to allow you to rewire cables of other manufacturers’ transducers and connect them to Transbridge. Each Transbridge channel may be used in either Full Bridge or the Half Bridge mode independently. For transducer types other than resistive bridges, such as active transistor circuits, magnetic, photocell or piezoelectric devices, the instrument’s differential amplifiers may still be used effectively for signal amplification in differential (full bridge) and single-ended (half bridge) modes. See WPI’s complete line of TRANSDUCERS for physiological measurements.

Specifications

Channels 4
Voltage amplification x1, x10, x100, x1000
Voltage offset adjustment ±50 mV
Noise .4 µV p-p (0.1 to 10 Hz, G=100)
Linearity ± .001% of FSR G=1;± .01% of FSR, G-=1000
Output voltage swing ±10 V
Maximum output current 2 mA
Input impedance , each input 1010 Ω
Transducer Excitation 10VDC (±5 V) approx.
Bandwidth , small signal 1 MHz (x1), 80 KHz (x10),10 KHz (x100), 1.0 KHz (x1000)
Fuse (Older models) 120 V: 0.12A, Slow, 0.25x1.25” USA
230 V: 0.06A, Slow, 0.25x1.25” USA
Fuse (2019 models) 120 V: 0.12A, Slow, 5 x 20 mm metric
230 V: 0.06A, Slow, 5 x 20 mm metric
Dimensions 21.6 x 13 x 25.44 cm
Shipping weight 5 kg

Accessories

FORT10G

FORT10G

Force Transducer 10g

View details...

FORT25

FORT25

Force Transducer 25g

View details...

FORT100

FORT100

Force Transducer 100g

View details...

FORT250

FORT250

Force Transducer 250g

View details...

FORT1000

FORT1000

Force Transducer 1000g

View details...

FORT5000

FORT5000

Force Transducer 5000g

View details...

Citations

RelatedItems

BRIDGE8

BRIDGE8

Bridge8 Transducer Amplifier Module

View details...

Our Clients Include:

GlaxoSmithKline
University College London
Novartis
Imperial College
University of Cambridge
University of Oxford

Keep in Touch

We promise NEVER to share your details with anyone. You can opt out at any time.