ISO-80
ISO80 Isolated Bio-Amplifier with active probe
- Overview
- Specifications
- Accessories
- Citations
- Related Products
Overview
There are 1 images available to view - click to enlarge and scroll through the product gallery.
ISO-80 Instruction Manual
/ Download as PDF
Benefits
- Ultra quiet DC power supply
- Intrinsic low susceptibility to ground loops
- High signal to noise ratio due to remote head stage
- Small footprint
- Stimulation/histological marking current
Applications
- Amplifying bio-potentials using metal microelectrodes
- Brain slice field potentials
- EAG (Electroantennogram)
- ERG (Electroretinogram)
- Monitor extracellular nerve action potentials
- Use for cell marking, stimulation or electrode cleaning
- In vivo cortical recording
ISO-80 Isolated Bio-Amplifier With Active Probe
The ISO-80 provides low noise AC coupled amplification and offers excellent recording performance for monitoring extracellular nerve action potentials in vitro and in living animals. The ISO-80 is provided with a remote headstage (1 m cable) which incorporates an electrode impedance test function and a constant current stimulator. The constant current stimulator can be used for cell marking, stimulation or electrode cleaning. Typical applications include measuring EMG, EEG, extracellular and action potentials in vitro or in vivo. The ISO-80 system is DC isolated from the subject ground and employs state of the art electro-magnetic shielding for improved noise rejection. The amplifier employs both high pass and low pass filtering with gain from 100 to 10,000. The lowest low-pass setting is 5 Hz and the upper passband is 10 kHz.
- Battery powered, rechargeable
- High pass and low pass filtering
- Active remote headstage
- AC only amplification
- Electrode impedance test function
- Electrode current generation with polarity select
- Variable output positioning
- The ISO-80P replacement probe does not need the ISO-80 to be sent in for calibration
Start-up kit included
Included with the ISO-80 is a Startup Kit containing the following accessories needed for basic metal electrode electrophysiology research:
- CBL102 Cable, BNC-to-3.5 mm plug 6 ft. (2m) (two)
- 5469 Adapter, mini-banana to 0.031 socket (two)
- 13388 Adapter, mini-banana to 2mm socket (two)
- 3294 Cable, ground clip to wire, 3 ft.
- 2033 Mini-banana plug, black
- 2034 Mini-banana plug, red
- 2035 Mini-banana plug solderable turrent (two)
- EP1 Ag/AgCl pellet (70 mm wire) 1 mm diam x 2.5 mm long
- M3301EH Electrode Holder, 14cm (two)
- 5470 0.031-inch jack on 12-inch wire (package of 4)
Specifications
Input Resistance | 1011Ω, Common Mode and differential |
Input Leakage Current | 50 pA, max. |
Amplification | x102, x103, x104 |
Common Mode Rejection Ratio | 100 dB typ. @ 50/60 Hz |
Equivalent Noise Signal Input | 0.4 µV rms (0.1-100 Hz) 2.0 µV rms (1 Hz - 10 kHz) |
Filter Settings:Low frequency | 5, 10, 100, 300 Hz |
Filter Settings:High frequency | 100 Hz, 1, 3, 10 kHz |
Max. Output Voltage Swing | ±8 V |
Electrode Impedance Range | 100 kΩ - 10 MΩ @ 300Hz |
Stimulation Current | 0 to ±20 µA (constant current) |
Maximum STIMULATION Voltage | ±15 V |
Maximum Electrode Voltage | ±40 V |
Displa y | 3.5-digit LCD |
BATTERY TEST | Low battery display |
Power | Two 9 V Ni-MH batteries & charger,supplied |
SHIPPING WEIGHT | 1.8 kg |
Request
Catalogue
Chat
Print