World Precision Instruments

Search the site by KEYWORD


Quick Finder


Testimonials

Janice Carter, University of Cambridge

The person in WPI I deal with is Julian Williams and he has been very helpful in sorting out any problems we may have and finding items that we require. He is very pleasant to deal with and I have used WPI for the last 8 years and I am very happy with the service that they provide us.
read more

ISO-80

ISO-80

ISO80 Isolated Bio-Amplifier with active probe



Choose Quantity
  • Overview
  • Specifications
  • Accessories
  • Citations
  • Related Products

Overview

ISO-80 Isolated Bio-Amplifier with active probe

There are 1 images available to view - click to enlarge and scroll through the product gallery.

ISO-80 Instruction Manual
/ Download as PDF

Benefits

  • Ultra quiet DC power supply
  • Intrinsic low susceptibility to ground loops
  • High signal to noise ratio due to remote head stage
  • Small footprint
  • Stimulation/histological marking current

Applications

  • Amplifying bio-potentials using metal microelectrodes
  • Brain slice field potentials
  • EAG (Electroantennogram)
  • ERG (Electroretinogram)
  • Monitor extracellular nerve action potentials
  • Use for cell marking, stimulation or electrode cleaning
  • In vivo cortical recording

ISO-80 Isolated Bio-Amplifier With Active Probe

The ISO-80 provides low noise AC coupled amplification and offers excellent recording performance for monitoring extracellular nerve action potentials in vitro and in living animals. The ISO-80 is provided with a remote headstage (1 m cable) which incorporates an electrode impedance test function and a constant current stimulator. The constant current stimulator can be used for cell marking, stimulation or electrode cleaning. Typical applications include measuring EMG, EEG, extracellular and action potentials in vitro or in vivo. The ISO-80 system is DC isolated from the subject ground and employs state of the art electro-magnetic shielding for improved noise rejection. The amplifier employs both high pass and low pass filtering with gain from 100 to 10,000. The lowest low-pass setting is 5 Hz and the upper passband is 10 kHz.

  • Battery powered, rechargeable
  • High pass and low pass filtering
  • Active remote headstage
  • AC only amplification
  • Electrode impedance test function
  • Electrode current generation with polarity select
  • Variable output positioning
  • The ISO-80P replacement probe does not need the ISO-80 to be sent in for calibration

Start-up kit included

Included with the ISO-80 is a Startup Kit containing the following accessories needed for basic metal electrode electrophysiology research:

  • CBL102 Cable, BNC-to-3.5 mm plug 6 ft. (2m) (two)
  • 5469 Adapter, mini-banana to 0.031 socket (two)
  • 13388 Adapter, mini-banana to 2mm socket (two)
  • 3294 Cable, ground clip to wire, 3 ft.
  • 2033 Mini-banana plug, black
  • 2034 Mini-banana plug, red
  • 2035 Mini-banana plug solderable turrent (two)
  • EP1 Ag/AgCl pellet (70 mm wire) 1 mm diam x 2.5 mm long
  • M3301EH Electrode Holder, 14cm (two)
  • 5470 0.031-inch jack on 12-inch wire (package of 4)

Specifications

Input Resistance 1011Ω, Common Mode and differential
Input Leakage Current 50 pA, max.
Amplification x102, x103, x104
Common Mode Rejection Ratio 100 dB typ. @ 50/60 Hz
Equivalent Noise Signal Input 0.4 µV rms (0.1-100 Hz) 2.0 µV rms (1 Hz - 10 kHz)
Filter Settings:Low frequency 5, 10, 100, 300 Hz
Filter Settings:High frequency 100 Hz, 1, 3, 10 kHz
Max. Output Voltage Swing ±8 V
Electrode Impedance Range 100 kΩ - 10 MΩ @ 300Hz
Stimulation Current 0 to ±20 µA (constant current)
Maximum STIMULATION Voltage ±15 V
Maximum Electrode Voltage ±40 V
Displa y 3.5-digit LCD
BATTERY TEST Low battery display
Power Two 9 V Ni-MH batteries & charger,supplied
SHIPPING WEIGHT 1.8 kg

Accessories


Choose Quantity
CBL102

CBL102

DAM Series, PM Series


Choose Quantity
2033

2033

Black Insulated Mini Banana Plug


Choose Quantity
2034

2034

Red Insulated Mini Banana Plug


Choose Quantity
5469

5469

Adapter Electrode 0.031 for DAM80P


Choose Quantity
2035

2035

Uninsulated Mini Banana Plug


Choose Quantity
ISO-80P

ISO-80P

Replacement ISO-80 Probe


Choose Quantity
3294

3294

Ground Wire for DAM80 Probe, Clip with 3 ft (0.9m) cable, no plug


Choose Quantity
13388

13388

Electrode adapter for DAM probes, miniature banana (male) - 2 mm jack

View details...

Citations

RelatedItems

DAM50

DAM50

DAM50 Bio-Amplifier, Low noise, battery-operated amplifier

View details...

DAM80

DAM80

DAM80 Bio-Amplifier with active probe

View details...

Our Clients Include:

GlaxoSmithKline
University College London
Novartis
Imperial College
University of Cambridge
University of Oxford

Keep in Touch

We promise NEVER to share your details with anyone. You can opt out at any time.