Accessories
Metal Microelectrodes
Superior microelectrodes for outstanding extracellular recording — tungsten, i...
Force Transducers
ez-gSEAL 100B Pressure Controller
Make the perfect seals for your patch-clamp recordings!
715P
Replacement probe for Duo 773 Electrometer - Port A.
- Instrument must be returned to WPI for free calibration with new probe.
- 10^15 Ohms Input Impedance
- Use in Port A
712P
Replacement probe for Duo 773 Electrometer - Port B.
- Instrument must be returned to WPI for free calibration with new probe.
- >10^11 Ohms Input Impedance
- Low Impedance
- Use in Port B
CAL900A
Pressure Calibration Chamber
- For use with the 900A Micropressure System
- The CAL900A creates a stable platform to test the system and calibrate the voltage output signal to known pressures for data recording
DAM80P
Replacement probe for DAM80 Bioamplifier
- Metal microelectrode adapter #5469 included with probe
5332
Replacement Liquid Trap
- Liquid trap designed for use with the 900A Micropressure System
- Must be positioned vertically
- Install between the micropipette holder and the 900A Pressure Pod
- Prevents moisture from entering the Pressure Pod
3517
2 Optional Shielded Modular Cables for DAM50 Bioamplifier
- Shielded cables
- For use with the DAM50
- RJ11 connector plugs into the Input port on the DAM50
- Other end of the cable is unterminated for use in your custom applications
13347
BNC to Double Banana Connector
- Connector A: Double-banana (male)
- Connector B: BNC (female)
- Cable: none
5470
0.031" Jack, 28 ga. wire, 12" (pkg of 4)
- 0.031" Socket on a 12" lead wire
- 28 gauge Wire
- Package of 4
- For use with the DAM80P probe
5482
Pins, 0.031" Gold-plated (pkg of 50)
- Width .079mm (.031")
- Length 9.88mm (.389")
- May be connected to 24-, 26- or 28-gauge wire
5483
Sockets, 0.031" Gold-plated (pkg of 50)
- Width .079mm (.031")
- Length 10.26mm (.404")
- Socket ID 0.51mm
- May be connected to 24-, 26- or 28-gauge wire
705PF
Replacement probe for 705 Electrometer.
Instrument must be returned to WPI for free calibration with new probe.
- Miniature gold-plated active probe
- Use with microelectrode holder
ISO-80P
Replacement ISO-80 Probe
ISO-80P is a high impedance probe that can be plugged into the PROBE INPUT socket of the ISO-80. Insert the electrodes that will connect with the preparation/subject under test into the two sockets—one red, one black—on the probe. The probe headstage is epoxy encapsulated within a miniature gold plated metal case. The use of a probe, close to a recording site, minimizes the shunt capacity normally associated with long wire leads from the electrode to the amplifier.
CAUTION: The probe headstage is sensitive to static discharge and can be damaged by a high voltage shock.
Nerve Cuff Electrodes
Nerve cuff electrodes are designed for reliable recording and/or stimulation of any ...