World Precision Instruments

Search the site by KEYWORD


Quick Finder


Testimonials

Researcher, Electrothermal

WPI offer a wide range of products designed for those working in the life science industry but just as importantly they offer great customer support and possess great product knowledge.
read more

Extracellular Applications Utilizing Glass Microelectrodes

Extracellular Applications Utilizing Glass Microelectrodes


For rare instances when using extracellular amplifiers with glass, you could use the setup shown below. In this setup, a DAM80 is shown, but you could easily substitute an ISO-80. Likewise, this setup shows the 2505 handle (1/4" - 6.3mm), but if you have a smaller micromanipulator, you may need the 5444 handle (3/16" - 4.8mm). In this illustration, MEH7W-10 is used, but any glass-size MEH7W could be used. (MEH7W-10 is 1.0mm glass, MEH7W-12 is 1.2mm glass, MEH7W-15 is 1.5mm glass and MEH7W-20 is 2.0mm glass.) EP2 is used for grounding in the illustration.

For single-ended applications, however, a 2033 wire adapter on the black connector socket can be connected to the 3294 cable. The tip used depends on your specific needs. In the illustration, TIP1TW1 was suggested. NOTE that the glass is not shown in the illustration below.


ISO-80

ISO-80

ISO80 Isolated Bio-Amplifier with active probe

View details...

DAM80

DAM80

DAM80 Bio-Amplifier with active probe

View details...


Choose Quantity
DAM80P

DAM80P

Replacement probe for DAM80 Bioamplifier

  • Metal microelectrode adapter #5469 included with probe


Choose Quantity
TIP1TW1

TIP1TW1

Pre-Pulled Glass Pipettes - 1µm ID 10/pk

  • Plain Shank
  • Tip ID: 1 µm
  • Glass OD: 1.0 mm
  • Filament: No
  • Fire Polished: Yes
  • Pipette individually vacuum packed
  • 10 per package

Pipettes are fabricated from Schott Duran borosilicate glass. Tip inner diameter tolerance +/- 20%. Short taper yields high strength. Nominal length approximately 50 mm. OD:ID ratio is 1.33:1.

A Certificate of Compliance is available for these microtips, please request one when placing your order.


Choose Quantity
EP2

EP2

2.0 mm dia. x 4 mm Ag/AgCl Electrode. Ag wire 50 mm long.


Choose Quantity
MEH7W

MEH7W

Microelectrode Holder, Male Connector, Wire Half-Cell, 2.0mm Pressure Port, Screw Cap. All holders are supplied for standard WPI single capillary tubing of 1.0, 1.2, 1.5 and 2.0 mm outside diameters. Please specify diameter of glass you are using when placing your order.


Choose Quantity
13388

13388

Electrode adapter for DAM probes, miniature banana (male) - 2 mm jack


Choose Quantity
2505

2505

Electrode Handle 6.3 mm. Microelectrode holder handle for use with WPI manipulators.


Choose Quantity
13620

13620

Low-noise cable for Microelectrode Holder, 2 ft (0.6 m), 2 mm gold pin - 2mm gold jack


Choose Quantity
5444

5444

Electrode Handle 4.8 mm. Microelectrode holder handle for use with Narishige and Zeiss manipulators.


Choose Quantity
3294

3294

Ground Wire for DAM80 Probe, Clip with 3 ft (0.9m) cable, no plug

  • Connector A: Clip
  • Connector B: none
  • Cable: 3 ft (0.9 m)


Choose Quantity
ISO-80P

ISO-80P

Replacement ISO-80 Probe

  • ISO-80P is a high impedance probe that can be plugged into the PROBE INPUT socket of the ISO-80. Insert the electrodes that will connect with the preparation/subject under test into the two sockets—one red, one black—on the probe. The probe headstage is epoxy encapsulated within a miniature gold plated metal case. The use of a probe, close to a recording site, minimizes the shunt capacity normally associated with long wire leads from the electrode to the amplifier.

    CAUTION: The probe headstage is sensitive to static discharge and can be damaged by a high voltage shock.

Our Clients Include:

GlaxoSmithKline
University College London
Novartis
Imperial College
University of Cambridge
University of Oxford

Keep in Touch

We promise NEVER to share your details with anyone. You can opt out at any time.