EVM-AC-03-03
EVOM™ Warming Plate - Minimize the effect of temperature fluctuation by taking TEER measurements at the physiological temperature.
- Overview
- Specifications
- Accessories
- Citations
- Related Products
Overview
There are 6 images available to view - click to enlarge and scroll through the product gallery.
EVM-AC-03-03 - EVOM™ Warming Plate Instruction Manual
/ Download as PDF
Features
- Compact 6, 12, 24, and 96 well plate warming platform
- Maintain sample temperature outside the incubator
- Fast temperature equilibration/stabilization for TEER measurement
Benefits of EVOM™ Warming Plate
- Maintain the sample plate temperature at 37°C, the same as the incubator temperature, while the resistance/ TEER values are measured with WPI’s EVOM™ Manual and a pair of chopstick electrodes, such as STX4 or STX HTS.
- Heat a sample well plate from room temperature to 37°C in less than 12 minutes
- Minimize the effect of temperature fluctuation by taking measurements at the physiological temperature
- Save time by eliminating the need for room temperature equilibration before measurement
- Warm a sample well plate to the (incubator like) temperature of 37 °C
TEER readings are known to be affected by fluctuations in the sample temperatures. Normal practice has been to take the sample plates out of the incubator and let the plate equilibrate for 20 minutes at room temperature before measuring samples. WPI’s EVOM™ Warming Plate allows you to maintain sample plate temperature at 37°C, the same as the incubator temperature, while the resistance/TEER values are measured with WPI’s EVOM™ Manual and chopstick electrodes, such as STX4 or STX HTS. Using the EVOM™ Warming Plate, the effect of temperature fluctuation is minimized, and the measurement can be taken at the physiological temperature. This also saves your time by eliminating the requirement of room temperature equilibration before measurement. The EVOM™ Warming Plate platform will accept either a 6 well plate, 12 well plate, 24 well plate or 96 well plate.
Specifications
Type | Description |
Temp stability | ±0.5 °C |
Display accuracy | 0.1 °C |
Timing range | 6 h 00 min |
Heat up time | < 12 min from room temperature |
Ideal heating plate temperature range | Room temperature + 11-18 °C |
Operating environment | Room temperature should be 20-25 °C and 35-50 % relative humidity |
Dimension (L x W x H) | 17 x 16 x 12 cm |
Power supply | 100-240 VAC, 50/60 Hz input to 24VDC-4A output |
Power | 96 W |
Weight | 1.6 Kg |