ISO-OXY-2
Oxygen Sensor - 2mm for use with TBR4100/TBR1025 Free Radical Analyzers
- Overview
- Specifications
- Accessories
- Citations
- Related Products
Overview
There are 1 images available to view - click to enlarge and scroll through the product gallery.
ISO-OXY-2/OXELP Instruction Manual
/ Download as PDF
- Gas permeable polymer membrane sleeve blocks liquids, ions and particulate matter
- Incorporated reference electrode
- For use with Apollo1000, Apollo4000, TBR4100 and TBR1025
- Response Time: < 10 sec (90%)
- Detection Limit: 0.1% to 100%
- Drift: < 1%/min
Benefits
- Clark type of oxygen sensor with tip size of 2 mm, can be used for very small volume O2 measurement
- Make direct quantitative measurements in biological samples
Applications
- Cell culture, cell suspensions
- Cell tissue measurements
Details
Make direct quantitative measurements in biological samples
This sensor incorporates WPI’s proprietary combination electrode technology whereby the oxygen-sensing element and separate reference electrode are encased within a single shielded sensor design. A gas-permeable polymer membrane is fitted over the end of the sleeve, which allows oxygen to pass while blocking liquids, ions and particulate matter.
Oxygen diffuses through the membrane. The voltage applied to the sensor is held at -0.7V when the monitoring device is on and the sensor is properly connected. The magnitude of the generated electrical current is determined by the rate of diffusion through the membrane. The rate is proportional to the partial pressure of oxygen outside the membrane. The current serves as a measure of the partial pressure of O2.
The ISO-OXY-2 is a 2.0 mm stainless steel sensor, with replaceable membrane sleeves (#5378) and an internal refillable electrolyte (#7326).
Specifications
APPLICATION | Cell cultures, cell suspensions |
SENSOR DIAMETER | 2.0 mm |
RESPONSE TIME | <10 SEC (90%) |
DETECTION LIMIT | 0.1 % to 100% |
DRIFT | <1%/min |
SENSITIVITY | N/A |
PHYSIOLOGICAL INTERFERENCE | None |
Accessories
5378
Electrode Sleeve Kit for OXELP and ISO-OXY-2 electrode. Contains four replacement sl...
5377
Replacement Start-up Kit for OXELP and ISO-OXY-2 electrode. Includes T-Adapter Kit 5...
Citations
X. Liu, C. Cheng, N. Zorko, S. Cronin, Y.R. Chen, J.L. Zweier "Biphasic modulationof vascular nitric oxide catabolism by oxygen" Am J Phhsiol Heart circ Physiol 287. 2004: H2421-H2426
Olson, K. R., Gao, Y., DeLeon, E. R., Arif, M., Arif, F., Arora, N., & Straub, K. D. (2017). Catalase as a sulfide-sulfur oxido-reductase: An ancient (and modern?) regulator of reactive sulfur species (RSS). Redox Biology, 12, 325–339. https://doi.org/10.1016/j.redox.2017.02.021
Hirai, T., Osamura, T., Ishii, M., & Arai, H. (2016). Expression of multiple cbb3 cytochrome c oxidase isoforms by combinations of multiple isosubunits in Pseudomonas aeruginosa. Proceedings of the National Academy of Sciences of the United States of America, 113(45), 12815–12819. https://doi.org/10.1073/pnas.1613308113
Park, Y. M., Lee, H. J., Jeong, J.-H., Kook, J.-K., Choy, H. E., Hahn, T.-W., & Bang, I. S. (2015). Branched-chain amino acid supplementation promotes aerobic growth of Salmonella Typhimurium under nitrosative stress conditions. Archives of Microbiology, 197(10), 1117–1127. https://doi.org/10.1007/s00203-015-1151-y