World Precision Instruments

Search the site by KEYWORD


Quick Finder


Testimonials

Researcher UCL, Institute of Ophthalmology

I am really impressed by your very high level of customer service. I got a problem of our pump recently and contacted the service. Julian Williams replied me immediately and tried to resolve the issue with good suggestions. Meanwhile, she loaned me a pump which enabled me to carry out my experime...
read more

ISO-NOP

ISO-NOP

Nitric Oxide Sensor - 2mm


Choose Quantity
  • Overview
  • Specifications
  • Accessories
  • Citations
  • Related Products

Overview

ISO-NOP

There are 1 images available to view - click to enlarge and scroll through the product gallery.

ISO-NOP Instruction Manual
/ Download as PDF

The original nitric oxide probe

Ideal for cell cultures, cell suspensions and many other applications.The ISO-NOP is a popular, robust and high performance sensor encased within a 2 mm diameter disposable stainless steel protective sleeve. The tip of the sleeve is covered with a NO-selective membrane. Replacement membrane sleeves can be purchased separately (WPI #5436) and require an internal electrolyte (WPI #7325).

NO‾3 and NO‾2 Detection

A simple change in experimental protocol will enable the ISO-NOP to be conveniently used for rapid accurate determination of nitrite (NO‾2) and nitrate (NO‾3) concentration in samples. Using this method a detection limit for NO‾2 or NO‾3 as low as 1nM is routinely possible.

Selectivity of WPI's NO sensors

The ideal NO sensor should be insensitive to other reactive species likely to be present within the measurement environment. Conventional Nafion coated carbon fiber NO sensor exhibits a large response to such species. WPI's unique NO sensor technology utilizes an novel surface membrane which amplifies the response to NO whilst eliminating responses to a vast range of reactive species, including nitrite, absorbic acid, hydrogen peroxide, catecolamines, and much more.

Specifications

Outside Diameter 2mm
Response Time   < 5 sec
Lowest Detection Limit/Range   1nM
Upper Detection Limit/Range   80uM (beyond 80uM, sensor accuracy is not guaranteed)
Nominal Sensitivity (New sensor) ≤2pA/nM  
Interferent (Selectivity Coefficient) NaNO2 (10^-6 or better)
Drift < 1pA/min
Poise Voltage 865mV
Typical Quiescent Baseline Current, 25°C 3,000pA  
Acceptable Baseline Range   1,000-8,000pA
Polarization Time   12+ hours  
Recommended Polarization Solution   0.1M KI/H2SO4
Physiological Interference   None

              

 

Accessories


Choose Quantity
7325

7325

ISO-NO Filling Solution, 10ml

View details...


Choose Quantity
5436

5436

Replacement sleeves for ISO-NOP electrode (2mm)

View details...

Citations

RelatedItems

TBR1025

TBR1025

One-Channel Free Radical Analyzer

View details...

TBR4100

TBR4100

Four-Channel Free Radical Analyzer

View details...

Our Clients Include:

GlaxoSmithKline
University College London
Novartis
Imperial College
University of Cambridge
University of Oxford

Keep in Touch