STXF-WSKMX-SET

STXF-WSKMX-SET

Incubator Set for wellplates, pre-mixed gas (5%CO2+95%Air), for manual/motorized stage with 160 x 110mm opening



Choose Quantity
  • Overview
  • Specifications
  • Accessories
  • Citations
  • Related Products

Overview

WSKMX STXG

There are 2 images available to view - click to enlarge and scroll through the product gallery.

  • For manual/motorized stage with 160 x 110mm opening

  • With built-in analog flow meter for premixed gas cylinder use (5%CO2+95%Air)

  • Sample temperature:30~40°C with Real-time Sample Feedback Regulation

  • Includes Dish Attachments and Fixing Lids as standard (For well-plate, 35mm dish, 60mm dish, slide glass/chamber slide/chambered coverglass)

 

Includes:

  • WSKMX Chamber
  • Lens Heater
  • Controller
  • Attachments and Lids for 35/50/60mm dish, chamber slide/coverglass, multi-wellplate
  • Feedback Sensor
  • Extension Wire for Sensor
  • Software STX-APP Install CD
  • USB Cable
  • Gas Tubes
  • Power Cable

Chamber WSKMX

Controller STXF

 

Specifications

     

STXG

with built-in gas mixer

STXF

with analogue flowmeter 

Temperature Temperature control PID control
Increments 0.1°C by digital switches
Setting method Touch Panel or PC
Possible temperature setting range Sample temperature

30°C~40°C

Top Heater 10°C~65°C
Bath Heater 10°C~50°C
Stage Heater 10°C~50°C
Lens Heater 10°C~45°C
Rise time 10 minutes to reach 50°C

Accuracy Within ±0.3°C at each heater surface(in our terms and conditions)
Sensor Pt 100
Humidity Humidification control Forced humidification by heating Bath Unit
Condensation prevention Top Heater equipped with glass heater

Gas

CO2 concentration range 5%~20%  
Control method PID control Precision needle valve
Accuracy Within ±0.1% Within±2% FS
Gas type 100% CO2 5%CO2
Input gas pressure 0.1Mpa~0.15MPa
Output gas pressure 160 ml/min 75 ml/min~
250 ml/min
Power source 100 V~240 V AC ±10% 50/60Hz
Maximum power consumption 110W 90W

Accessories