Microx 4 Trace

Microx 4 Trace

Stand-alone Fiber Optic Oxygen Meter for Contactless and Micro-invasive Measurements



Choose Quantity
  • Overview
  • Specifications
  • Accessories
  • Citations
  • Related Products

Overview

Microx 4 Trace Microx 4 Trace Dimensions

There are 2 images available to view - click to enlarge and scroll through the product gallery.

Stand-alone Fiber Optic Oxygen Transmitter

  • For use with non-invasive sensors, probes & microsensors
  • Measure from 3 ppb to 100 % oxygen with one device
  • Straightforward measurement due to unique sensor ID
  • Simple calibration via barcode scan
  • 16 GB internal memory
  • Compensation of temperature, pressure and salinity
  • Energy management for long term measurements
  • Optional database supported software offers simultaneous control of multiple devices

The Microx 4 trace is a completely stand-alone, portable fiber optic oxygen meter. It can be used with non-invasive sensors & dipping probes (1 mm fiber), and oxygen microsensors (200 µm fiber) in different designs. This oxygen meter is compatible with the wide range of sensors type PSt7 (detection limit 15 ppb, 0 – 100 % oxygen), and the trace oxygen sensors type PSt8 (detection limit 3 ppb, 0 – 10 % oxygen). The integrated barcode reader allows sensor recognition and calibration with just one scan. With the implemented sensor management system data of up to 100 sensors can be stored. Microx 4 trace has 16 GB internal memory which allows prolonged computer-independent operation. This oxygen meter is delivered with the PreSens Datamanager software for easy data exchange with a PC, data management and export.

Applications

Environmental & Biological Research

The handheld Microx 4 & Microx 4 trace are ideal tools for field reasearch, and can be applied for gaseous or dissolved oxygen measurements. Combined with different types of dipping probes, or oxygen microsensors they allow e. g. water quality assessment, respiration measurements, or measurements inside tissue. These oxygen meters are applicable wherever precise oxygen measurement is needed. With their splash proof, robust housing the oxygen meters can be used in harsh environments. Special energy settings for long term measurements, the almost unlimited storage capacity or features like graphical display of your measurements allow for prolonged and comfortable computer-independent use.

Medical & Life Science Research

Microx 4 & Microx 4 trace can be used with oxygen microsensors in different designs. These sensors allow for precise on the spot measurement and profiling inside tissue constructs. PreSens oxygen microsensors are already applied in several tissue engineering applications. Implantable microsensors without any additional housing are ideally suited for customized application set-ups, integration in catheters or direct implantation into soft tissue. As the oxygen meters can also be applied with sensor spots, even non-invasive measurements inside cell culture vessels can be performed, without the risk of contamination.

The Ideal Tool for Packaging & Quality Control

Oxygen inside packaging can lead to oxidative deterioration and shorten the shelf life of products. The portable, handheld Microx 4 & Microx 4 trace are ideally suited for quality control in the food & beverage industries, and can be applied in different stages of production. The oxygen sensors in various designs can be integrated in pipes, containers or directly held into samples taken for quality control. Calibration and sensor recognition via barcode scan will speed up the work flow when investigating oxygen ingress in hundreds of containers and packages. Applied with the needle-type oxygen microsensors the oxygen content in small scale headspace packages or non-transparent containers can be determined with the oxygen meters.

Oxygen Measurements in Biofilms & Sediments

Microx 4 & Microx 4 trace can be used with oxygen microsensors in different designs, which allow on the spot measurements. Needle-type oxygen microsensors housed in a syringe needle can be inserted in biofilms or sediments for oxygen profiling. Perform exact online oxygen measurements in different depths of your sample. Combined with micromanipulators the oxygen microsensors can be inserted in µm steps for exact positioning. Robust dissolved oxygen probes are available also, for easy application in sediments in the lab or out in the field.

Specifications

Oxygen sensors PSt7 and PSt8 (optical ST connector)
Temperature sensor Pt100 temperature connector (sensor not included)
Temperature performance From 0 °C to + 50 °C, resolution ± 0.1 °C
Power supply 4 AA nickel-metal hybrid cells (min. 2200 mAh)
use only AC adapter (5 VDC / min. 1 A) supplied for recharging
Max. battery operating time 16 hrs. (3 sec. interval measurement, default LED intensity, display backlight OFF, at room temperature)
Temperature: operating / storage from 0 °C to + 50 °C / from - 20 °C to + 70 °C
Relative humidity Up to 80 % (non condensing)
Dimensions 37 mm x 180 mm x 119 mm
Weight 0.65 kg (w/o batteries & protection kit)
0.78 kg (with batteries & protection kit)
Digital interface USB interface (cable included)
Display 3.5 '' color TFT, 320 x 240 pixel
Internal memory 16 GB memory (~ 40,000,000 data sets) export via included software