World Precision Instruments

Search the site by KEYWORD


Quick Finder


Testimonials

Researcher, Imperial College National Heart and Lung Institute

Julian was fantastic, he patiently walked me through the steps for diagnosing issues with our syringe pump. We found it was a simple belt that was broken and he sent out a replacement part the same day.
read more

7610A Temperature Controlled Standard Tissue Bath

7610A Temperature Controlled Standard Tissue Bath

Temperature Controlled Standard Tissue Bath



Choose Quantity
  • Overview
  • Specifications
  • Accessories
  • Citations
  • Related Products

Overview

7610A 7610A on 7000smz

There are 2 images available to view - click to enlarge and scroll through the product gallery.

Traditionally once removed from the animal, tissue is immediately cooled to close to +4° C to lower the oxygen demand and prevent anoxia. This has the added advantage with delicate tissues of increasing the stiffness of the tissue allowing for a more robust slice. This can be done with passive cooling by applying ice to the outer icebath (included as standard) or use of the 7610A Tissue Cooler Bath.

The advantage of the 7610A is constant tight control of the bath temperature over long periods without the requirement to refresh the ice or disturb the tissue sample.

Features

The control unit supplies power to the 'Peltier' thermoelectric elements in the base of the tissue bath. These act as energy transfer units so that heat is drawn off, through the heat exchanger and removed by tap water flow which runs to waste. The unit uses P.I.D. (proportional integral derivative) temperature control to take the bath temperature to within 0.5° C at the point of measurement. The temperature feedback thermistor is located in the bath floor and software calculates an offset automatically.

Utilitizes the standard inner stainless steel tissue bath

Specifications

Display Resolution: 0.1° C
Temperature Accuracy: +/- 1° C
Temperature Range: +8-0° C**
Voltage Requirements: 230V 50Hz or 115V 60Hz
Power Rating: 60W
Inlet Fuse Rating: 2A
** Actual temperatures achievable will be dependent upon the solutions used and local temperature conditions. For optimal cooling; inlet water temperature should be below 25° C and flow rate should be greater than 400ml/min

Accessories

Citations

RelatedItems

Our Clients Include:

GlaxoSmithKline
University College London
Novartis
Imperial College
University of Cambridge
University of Oxford

Keep in Touch