AL-DUAL-AL-1010

Dual Aladdin High Pressure Pump System (Two Aladdin AL-1010 SyringeONE:100 High Pressure Syringe Pumps with sync cable for reciprocating use)



Choose Quantity
  • Overview
  • Specifications
  • Accessories
  • Citations
  • Related Products

Overview

AL-DUAL-AL-1010 Dual Aladdin High Pressure Pump System

There are 1 images available to view - click to enlarge and scroll through the product gallery.

AL-DUAL-AL-1010 Instruction Manual
/ Download as PDF

  • Includes 2 x AL-1010 pumps and sync cable for reciprocating use
  • Each pump accepts syringe sizes: 1-60mL, or 0.5-5 uL
  • Programmable, economical, verstaile
  • Network, control, and monitor up to 100 pumps with one computer

The Dual System allows the two pumps to communicate with each other through a synchronization cable. The system is flexible and can the pumps casn be configured to operate in:

  • Continuous flow (push/pull configuration requires p-dkit optional check valve set)
  • Emulsification
  • Independently

Each AL-1010 pump offers

  • Automatic dispensing of small volumes
  • Very precise, reproducible flow rate control
  • Displays total volume dispensed in mL or µL units
  • Selectable infusion/withdrawal rate units (mL/hr, µL/hr, mL/min, µL/min)
  • Infusion rate can be changed while pumping
  • Program pump via keypad or from a computer
  • Highly controllable – program sequences without a computer (holds up to 41 programming phases)
  • Motor stall detection

To meet the demands of a busy lab Aladdin Pumps offer exceptional value providing versatility and reliability for accurately dispensing media down into the nanoliter range.

The Aladdin AL-1010 is a high pressure programmable single channel infusion / withdrawal syringe pump. It has a metal casing to provide stability, ensuring less vibration is transferred to the syringes. Setup is easy using the pumps keypad or via a computer with optional PC to pump cable (GN-PC7 or GN-PC25).

The Aladdin AL-1010 can run complex programs with up to 41 pumping phases can be set to change pumping rates; set dispensing volumes; insert pauses; control and respond to external signals; sound the buzzer. (For Linear/Gradient programs use AL-1010X)

Example flow rates

Syringe Size Maximum Rate Minimum Rate
0.5 µL 91.83 µL/hr 0.001 µL/hr
1 mL 190.4 mL/hr 1.453 µL/hr
3 mL 806.1 mL/hr 6.151 µL/hr
5 mL 1341 mL/hr 10.24 µL/hr
10 mL 2188 mL/hr 16.7 µL/hr
20 mL 3479 mL/hr 26.55 µL/hr
30 mL 4539 mL/hr 34.64 µL/hr
60 mL 7635 mL/hr 58.3 µL/hr
140 mL 208.3 mL/min 95.37 µL/hr

 



Specifications

SYRINGE SIZES 1-60 mL (140 mL partially filled)
NUMBER OF SYRINGES 1
MOTOR TYPE Step Motor, 1/8 to 1/2 step modes
STEPS PER REVOLUTIONS 200
STEPPING (min. max.) 0.425 µm (1/8 stepping) to 1.701 µm (1/2 stepping)
MOTOR TO DRIVE SCREW RATIO 15/28
SPEED (max./min.) 18.4 cm/min / 0.0084 cm/hr
PUMPING RATES 6120 mL/hr with 60mL syringe, to 1.459 µL/hr with 1mL syringe
MAXIMUM FORCE 100 lb at min. speed, 18 lb at max. speed
NUMBER OF PROGRAM PHASES 41
RS-232 PUMP NETWORK 100 pumps maximum
POWER supply Wall adapter 12V DC @ 1000mA
DIMENSIONS 22.9 x 14.6 x 11.4 cm (8.75 x 5.75 x 4.5 in.)
WEIGHT 1.6 kg (3.6 lb)

Accessories


Choose Quantity
GN-NET7

GN-NET7

Pump-to-pump Network Cable, 7 ft for Aladdin series pumps

View details...


Choose Quantity
GN-NET25

GN-NET25

Pump-to-pump Network Cable, 25 ft for Aladdin series pumps

View details...


Choose Quantity
GN-PC25

GN-PC25

PC to pump cable, 25 ft for Aladdin series pumps

View details...


Choose Quantity
ADPT2

ADPT2

Footswitch for Aladdin programmable syringe pumps

View details...


Choose Quantity
GN-PC7

GN-PC7

PC to pump cable, 7 ft for Aladdin series pumps

View details...


Choose Quantity
GN-TTL-1

GN-TTL-1

Pump-to-pump reciprocating cable for Aladdin series pumps

View details...


Choose Quantity
P-DKIT

P-DKIT

Dual Pump Plumbing Kit

View details...

Citations

Birngruber, T., & Ghosh, A. (2013). Cerebral open flow microperfusion: A new in vivo technique for continuous measurement of substance transport across the intact blood–brain barrier. Clinical and  …. Retrieved from https://onlinelibrary.wiley.com/doi/10.1111/1440-1681.12174/full

Ferreira, D., Reis, R., & Azevedo, H. (2013). Peptide-based microcapsules obtained by self-assembly and microfluidics as controlled environments for cell culture. Soft Matter. Retrieved from https://pubs.rsc.org/EN/content/articlehtml/2013/sm/c3sm51189h

Herricks, T., Avril, M., Janes, J., Smith, J., & Rathod, P. (2013). Clonal Variants of Plasmodium falciparum Exhibit a Narrow Range of Rolling Velocities to Host Receptor CD36 under Dynamic Flow Conditions. Eukaryotic cell. Retrieved from https://ec.asm.org/content/12/11/1490.short

Maya, H., Vincent, M., & Nötzli, S. (2013). Increased porosity of electrospun hybrid scaffolds improved bladder tissue regeneration. …  Research Part A. Retrieved from https://onlinelibrary.wiley.com/doi/10.1002/jbm.a.34889/full

Tõnurist, K., Thomberg, T., & Jänes, A. (2013). Polymorphic Behavior and Morphology of Electrospun Poly (Vinylidene Fluoride) Separator Materials for Non-Aqueous Electrolyte Based Electric Double Layer. ECS  …. Retrieved from https://ecst.ecsdl.org/content/50/45/49.short

Tõnurist, K., Thomberg, T., Jänes, A., & Lust, E. (2013). Specific Performance of Electrical Double–Layer Capacitors Based on Different Separator Materials and Non–Aqueous Electrolytes. ECS Transactions. Retrieved from https://ecst.ecsdl.org/content/50/43/181.short

Zander, N., & Orlicki, J. (2013). Electrospun polycaprolactone scaffolds with tailored porosity using two approaches for enhanced cellular infiltration. Journal of Materials  …. Retrieved from https://link.springer.com/article/10.1007/s10856-012-4771-7

Zhang, J., Jiang, D., & Peng, H. (2014). A pressurized filtration technique for fabricating carbon nanotube buckypaper: Structure, mechanical and conductive properties. Microporous and Mesoporous Materials. Retrieved from https://www.sciencedirect.com/science/article/pii/S1387181113005192

Zhang, J., Jiang, D., Peng, H., & Qin, F. (2013). Enhanced mechanical and electrical properties of carbon nanotube buckypaper by in situ cross-linking. Carbon. Retrieved from https://www.sciencedirect.com/science/article/pii/S000862231300568X

RelatedItems

AL-1000

AL-1000

Aladdin SyringeONE Programmable Syringe Pump

View details...

Our Clients Include:

GlaxoSmithKline
University College London
Novartis
Imperial College
University of Cambridge
University of Oxford

Keep in Touch

We promise NEVER to share your details with anyone. You can opt out at any time.