AL-8060
Aladdin SyringeONE:200 High Pressure (200 lb), High Speed Programmable Syringe Pump
- Overview
- Specifications
- Accessories
- Citations
- Related Products
Overview
There are 1 images available to view - click to enlarge and scroll through the product gallery.
Al-8060 Aladdin Pump Instruction Manual
/ Download as PDF
Built for Strength
-
Fast prime and purge
-
Adjustable force dial
-
Program end points with two adjustable limit switches
-
Center Acme Leadscrew with a solid nut
-
Clamp lock holds syringe tightly in channel
-
Designed to hold large syringes up to 200mL
-
Dispensing accuracy to ± 1%
-
Easy-to-use keypad interface
-
Infusion and withdrawal
-
Fully programmable; automation capable
-
Operates stand-alone or computer controllable
-
Accepts external inputs to trigger events
-
Foot Switch (optional) for hands-freeoperation
-
Network, control and monitor up to 100 pumps from one computer port
Channels | 1 |
Type | Infusion / Withdrawal |
Flow Range | from 0.003 µL/hr (0.5 µL syringe) to 1416 mL/min (200 mL syringe) |
Dispensing Accuracy | ±1% |
Syringe Sizes Accepted | 0.5 µL to 140 mL or 200 mL partially filled |
Linear Force | Ultra High (200 lb at low speed; 100 lb at maximum speed) |
To meet the demands of a busy lab Aladdin Pumps offer exceptional value providing versatility and reliability for accurately dispensing media down into the nanoliter range.
The AL-8060 SyringeONE:200 High Pressure Programmable Syringe Pump is designed with stainless steel syringes in mind for applications with strong back pressure or higher fluid viscosity, such as emulsification processes. The syringe pump holds one syringe from 0.5μL to 140mL and up to 200mL when syringe is partially filled. The AL-8060 operates independently and is programmable through its keypad. It can be configured with complex programs with up to 41 pumping phases set to change pumping rates; set dispensing volumes; insert pauses; control and respond to external signals; sound the buzzer. (For Linear/Gradient programs use AL-8060X)
Pumping programs can be uploaded and controlled from a computer via an RS-232 Serial Port (RS-232 Pump-to-PC Primary Network Cable –purchase CBL-PC-PUMP-7). An RS-232 to USB Converter Cable is available (purchase CBL-USB232). A pumping program generator and terminal emulator software are available as freedownloads from our website. For advanced control, consider the SyringePumpPro software for configuration and control of multiple pumps, logging pump activity and sending commands to selected pumps.
Example flow rates
Syringe Size | Maximum Rate | Minimum Rate |
0.5 µL | 150.1 µL/hr | 0.001 µL/hr |
1 mL | 15.62 mL/min | 6.777 µL/hr |
3 mL | 65.89 mL/min | 28.7 µL/hr |
5 mL | 109.6 mL/min | 47.76 µL/hr |
10 mL | 178.8 mL/min | 77.89 µL/hr |
20 mL | 284.4 mL/min | 123.9 µL/hr |
30 mL | 371.0 mL/min | 161.6 µL/hr |
50 mL | 603.3 mL/min | 262.7 µL/hr |
140 mL | 1021 mL/min | 444.9 µL/hr |
Specifications
Syringe Size | Maximum Rate | Minimum Rate |
0.5 µL | 150.1 µL/hr | 0.001 µL/hr |
1 mL | 15.62 mL/min | 6.777 µL/hr |
3 mL | 65.89 mL/min | 28.7 µL/hr |
5 mL | 109.6 mL/min | 47.76 µL/hr |
10 mL | 178.8 mL/min | 77.89 µL/hr |
20 mL | 284.4 mL/min | 123.9 µL/hr |
30 mL | 371.0 mL/min | 161.6 µL/hr |
50 mL | 603.3 mL/min | 262.7 µL/hr |
140 mL | 1021 mL/min | 444.9 µL/hr |
Accessories
Citations
Camargo, C. de, & Shiroma, L. (2016). Turbulence in microfluidics: Cleanroom-free, fast, solventless, and bondless fabrication and application in high throughput liquid-liquid extraction. Analytica Chimica …. Retrieved from https://www.sciencedirect.com/science/article/pii/S0003267016310492
Daulton, R., & Hintze, P. (2016). Instrument for Analysis of Organic Compounds on Other Planets. Retrieved from https://ntrs.nasa.gov/search.jsp?R=20160006046
RelatedItems
AL-1200
Aladdin SyringeTWELVE Programmable 12 Channel Syringe Pump - Holds 2, 4, 6, 8, 10 or...
AL-1600
Aladdin SyringeSIX Programmable 6 Channel Syringe Pump - Holds 2, 4 up to 140 cc or ...
AL-1800
Aladdin SyringeEIGHT Programmable 8 Channel Syringe Pump - Holds 2, 4, 6 or 8 syring...
AL-4000
Aladdin SyringeTWO Programmable Double Syringe Pump - holds two syringes of up to 60...
AL-DUAL-AL-1000X
Continuous Aladdin Pump System (Two Aladdin AL-1000X SyringeONE NeXtGen Syringe Pump...
Request
Catalogue
Chat
Print