World Precision Instruments

Search the site by KEYWORD


Quick Finder


Testimonials

Nicholas James, King's College London

Customer service was always quick and very helpful. Products all arrived quickly, were fully set up for us and have proved to be of good quality.
read more

STXG-WSKMX-E

STXG-WSKMX-E

Incubator Set for wellplates, adjustable CO2, for manual/motorized stage with 160 x 110mm opening



Choose Quantity
  • Overview
  • Specifications
  • Accessories
  • Citations
  • Related Products

Overview

WSKMX STXG

There are 2 images available to view - click to enlarge and scroll through the product gallery.

  • For manual/motorized stage with 160 x 110mm opening
  • With built-in digital gas mixer for 100% CO2 gas cylinder use, CO2 concentration adjustable between 5.0 - 20.0% 
  • Sample temperature:30~40°C with Real-time Sample Feedback Regulation
  • Includes Dish Attachments and Fixing Lids as standard For well-plate, 35mm dish, 50/60mm dish, slide glass/chamber slide/chambered coverglass)

 

Includes:

  • WSKMX Chamber
  • Lens Heater
  • Controller
  • Attachments and Lids for 35/50/60mm dish multi-wellplate
  • External Sensor
  • Extension Wire for Sensor
  • Gas Tubes
  • Power Cable

(optional Dish holder for chamber slide/coverglass, Sampel Feedback regulation, Data logging software)

Chamber WSKMX

Controller STXG

Specifications

     

STXG

with built-in gas mixer

STXF

with analogue flowmeter 

Temperature Temperature control PID control
Increments 0.1°C by digital switches
Setting method Touch Panel or PC
Possible temperature setting range Sample temperature

30°C~40°C

Top Heater 10°C~65°C
Bath Heater 10°C~50°C
Stage Heater 10°C~50°C
Lens Heater 10°C~45°C
Rise time 10 minutes to reach 50°C

Accuracy Within ±0.3°C at each heater surface(in our terms and conditions)
Sensor Pt 100
Humidity Humidification control Forced humidification by heating Bath Unit
Condensation prevention Top Heater equipped with glass heater

Gas

CO2 concentration range 5%~20%  
Control method PID control Precision needle valve
Accuracy Within ±0.1% Within±2% FS
Gas type 100% CO2 5%CO2
Input gas pressure 0.1Mpa~0.15MPa
Output gas pressure 160 ml/min 75 ml/min~
250 ml/min
Power source 100 V~240 V AC ±10% 50/60Hz
Maximum power consumption 110W 90W