World Precision Instruments

Search the site by KEYWORD


Quick Finder


Testimonials

Researcher UCL, Institute of Ophthalmology

I am really impressed by your very high level of customer service. I got a problem of our pump recently and contacted the service. Julian Williams replied me immediately and tried to resolve the issue with good suggestions. Meanwhile, she loaned me a pump which enabled me to carry out my experime...
read more

MS2

MS2

Perfusion of slice on both sides for upright microscope



Choose Quantity
  • Overview
  • Specifications
  • Accessories
  • Citations
  • Related Products

Overview

MS2

There are 1 images available to view - click to enlarge and scroll through the product gallery.

The MS2 is similar in construction to the MS1 chamber offering clearance for rotary and swing type microscope objective turrets. The central area has a #2 cover glass bottom with a 2 mm gap above it where a piece of replaceable nylon netting is trapped by a ’C’ ring (similar to BSC3 construction). Brain slices rest on the top of the nylon netting allowing both sides of the slice to be bathed with solution. The solution enters from one side and is passed through a buffer material to smooth out flow and exits via a slotted steel ‘L’ tube to aspirate out to a vacuum line. Flow rates from around 2ml/min and upwards keep the overall dead-space low for expensive drug exchanges. The chamber can be mounted on an upright microscope stage with normal condenser optics from below. Only the central 18 mm diameter area is flooded with solution contained within  the ‘C’ ring above trapping the netting where the slice rests.  The exit of solution is under the closed side of the ‘C’ ring so that fluid is made to flow over the slice and down to the exit channel. This ensures that the input solution path is both above and below the slice.

Schematic


 
Parts description


MS2 Slice chamber show in cross section. Slices rest on removable netting (RED) and perfusion solution enters via buffer material (nylon mesh) to one side. Solution enters both above and below slice but exits below the ‘C’ ring at the opposite end of the ‘C’ ring opening. A steel suction needle with a slot whose height is adjustable by turning sets the fluid level. Fluid is maintained constantly above the netting with a flow rate of up to 6ml/min and with a suction line attached to the exit needle.

Specifications

Accessories

Citations

RelatedItems

Our Clients Include:

GlaxoSmithKline
University College London
Novartis
Imperial College
University of Cambridge
University of Oxford

Keep in Touch

We promise NEVER to share your details with anyone. You can opt out at any time.