World Precision Instruments

Search the site by KEYWORD


Quick Finder


Testimonials

Dr Gary Lawrence, Dublin City University

WPI are my preferred supplier for tissue and cell recording instrumentation. In my experience, WPI representatives have an excellent level of technical expertise and they have always responded in a timely manner with the most helpful, patient and instructive advice to aid the development of the o...
read more

Flexible Implantable Probes (Type T Thermocouple)

Flexible Implantable Probes (Type T Thermocouple)

Flexible Implantable Microprobes are implantable in semi-solids and tissue with needle (supplied). Also for immersion in various solutions and rectal temperatures of small animals. Totally sheathed in chemical resistant Teflon. Max Temp. 150°C. Isolated. 


Features

  • Type T thermocouple
  • Implantable in semi-solids and tissue
  • Small with fast response time
  • Isolated
  • Temperature range -100°C to 150°C
  • ± 0.1°C accuracy over physiological range
  • Suitable for sterilization by autoclave, ETO gas, Gluteraldehyde or Isoprophyl Alcohol

Options

  • 23ga needile diameter 0.025" (0.63mm)
  • 26ga needle diameter 0.018" (0.46mm)
  • 29ga needle diameter 0.013" (0.33mm)

The microprobe can be inserted through the supplied needle.

All flexible implantable microprobes are ecapsulated in Teflon apart from IT-1E which has the sensor bead exposed.

Order code Description
IT-14 Flexible Implantable Microprobe with 14ga needle (supplied), 0.050" Dia, 150°C Max Temp, 0.3s Time Constant, 3' lead length
IT-18 Flexible Implantable Microprobe with 14ga needle (supplied), 0.025" Dia, 150°C Max Temp, 0.1s Time Constant, 3' lead length
IT-18EXLONG Flexible Implantable Microprobe with 14ga needle (supplied), 0.025" Dia, 150°C Max Temp, 0.1s Time Constant, 10' lead length
IT-21 Flexible Implantable Microprobe with 21ga needle (supplied), 0.016" Dia, 150°C Max Temp, 0.08s Time Constant, 1' lead length
IT-23 Flexible Implantable Microprobe with 23ga needle (supplied), 0.011" Dia, 150°C Max Temp, 0.005s Time Constant, 3' lead length
IT-1E Flexible Implantable Microprobe with 14ga needle (supplied), 0.009" Dia, 150°C Max Temp, 0.005s Time Constant, 3' lead length, Exposed bead
IT-24P Ultra Fine Flexible Implantable Microprobe 24ga, 0.011" Dia, 70°C Max Temp, 0.004s Time Constant, 3' lead length

 

Time constant is defined as the time  required to reach 63% of final temperature  in liquid.  An accurate reading is obtained  when the reading stops changing, typically  5-10 time constants.

Maximum Temperature refers to intermit tent use of a probe. When probe is used for continuous measurements, maximum temperature should bereduced by 25%.

Applications

Flexible Teflon microprobes are used for implantation in tissue, in spectrophotometer cuvettes, rectally in neonatal mice, in water baths, PCR thermal cyclers, etc. Also, measure animal rectal temperatures during surgical procedures and pyrogen testing or skin temperature measurement during exercise physiology studies.

Probe Sterilization Methods

The flexible implantable microprobes and animal rectal probes are all designed to withstand sterilization by ETO gas and gluteraldehyde solution.



Choose Quantity
IT-14

IT-14

Flexible Implantable Microprobe with 14ga needle (supplied)

  • 0.050" Dia
  • 150°C Max Temp
  • 0.3s Time Constant
  • 3' lead length

Designed for high accuracy on extremely small specimens such as insects, seeds, etc. Maximum insertion depth 1/8". Totally sheathed in chemical resistant Teflon.


Choose Quantity
IT-18

IT-18

Flexible Implantable Microprobe with 14ga needle (supplied)

  • 0.025" Dia
  • 150°C Max Temp
  • 0.1s Time Constant
  • 3' lead length

Designed for high accuracy on extremely small specimens such as insects, seeds, etc. Maximum insertion depth 1/8". Totally sheathed in chemical resistant Teflon.


Choose Quantity
IT-18EXLONG

IT-18EXLONG

Flexible Implantable Microprobe with 14ga needle (supplied)

  • 0.025" Dia
  • 150°C Max Temp
  • 0.1s Time Constant
  • 10' lead length

Designed for high accuracy on extremely small specimens such as insects, seeds, etc. Maximum insertion depth 1/8". Totally sheathed in chemical resistant Teflon.


Choose Quantity
IT-21

IT-21

Flexible Implantable Microprobe with 21ga needle (supplied)

  • 0.016" Dia
  • 150°C Max Temp
  • 0.08s Time Constant
  • 1' lead length

Designed for high accuracy on extremely small specimens such as insects, seeds, etc. Maximum insertion depth 1/8". Totally sheathed in chemical resistant Teflon.


Choose Quantity
IT-23

IT-23

Flexible Implantable Microprobe with 23ga needle (supplied)

  • 0.011" Dia
  • 150°C Max Temp
  • 0.005s Time Constant
  • 3' lead length

For ultra fast measurements and for use on micro-size specimens. Tissue implantable with 23ga. Needle (supplied). Rather fragile


Choose Quantity
IT-1E

IT-1E

Flexible Implantable Microprobe with 14ga needle (supplied)

  • 0.009" Dia
  • 150°C Max Temp
  • 0.005s Time Constant
  • 3' lead length

As IT-18 sensor except bead exposed. Combines ultra-fast reponse of IT-23 with sheath strength of IT-18


Choose Quantity
IT-24P

IT-24P

Ultra Fine Flexible Microprobe with 24ga needle (supplied)

  • 0.011" Dia
  • 70°C Max Temp
  • 0.004s Time Constant
  • 3' lead length

Ultra Fine Flexible Microprobe with tiny, 24 gauge polyurethane coated wire with polyester insulated thermocouple bead. For research applications to measure temperature in animal brains and other tissue. Fairly fragile, but very fast responding.