World Precision Instruments

Search the site by KEYWORD


Quick Finder


Testimonials

Researcher, Imperial College National Heart and Lung Institute

Julian was fantastic, he patiently walked me through the steps for diagnosing issues with our syringe pump. We found it was a simple belt that was broken and he sent out a replacement part the same day.
read more

7000smz-2

7000smz-2

Top of the range high precision, vibrating microtome. The is the finest tissue slicer in the world for preparations for visual patch clamping or high resolution imaging.


  • Overview
  • Specifications
  • Accessories
  • Citations
  • Related Products

Overview

7000smz-2

There are 1 images available to view - click to enlarge and scroll through the product gallery.

Our top of the range high precision, vibrating microtome (vibrotome for short), this is the finest tissue slicer in the world for preparations for visual patch clamping or high resolution imaging. The 7000smz series Vibrating microtome has been the instrument of choice for many labs for 10 years - over 450 labs and counting!

Using our microtomes, research detailing sectioning for visual patching of neurological tissue, heart, lung, and tissue scaffolds have all been published. The 7000smz-2 microtome represents significant advances with higher precision at a lower cost.

The vibrating mechanism of the 7000smz-2 microtome delivers unprecedented accuracy with nearly silent operation. Every machine is tested before dispatch by our in-house measurement devices and each machine is supplied with its own z-axis calibration checker.

The effect of excessive Z-axis deflection on the health and viability of the tissue preparation has been much discussed since the publication of Geiger et al (2003) and the Campden 7000smz-2 tissue slicer, with ≤ 1µm Z-axis de?ection across a wide range of vibration speeds and amplitudes, delivers healthy viable sections every time.

The user interface is easy and versatile (with no foot switch unlike previous models) and offers simple operation at the push of a button or a range of changeable parameters for the expert user. The Campden 7000smz-2 also provides longevity of performance, as not only does the slicer give ≤ 1 µm performance out of the box, but the advance vibrating mechanism does not contain bearings and other elements subject to wear. Thus it will retain the ≤ 1 µm z-ad performance for years to come, giving you consistency in your biological preparation, without the need for expensive servicing.

Holding the tissue close to 4° C must continue throughout the slicing procedure. This can be done with passive cooling where a known amount of ice is used to maintain the cooled a.c.s.f. or with an electronically controlled thermo-electric Tissue Bath Cooler (7610A).

We have developed both ceramic and stainless steel microtome blades, alongside the machine, so that the grinding and honing facets for the blade edge are matched to the blade downward angle of orientation to the tissue. The ceramic blades have a particular advantage when slicing brain tissue older than 30 days. These ceramic microtome blades also have a second advantage in that unlike stainless blades, these do not have to be replaced after each tissue sample.

Other options include an LED cold light and magnifier or scope for clear observation whilst slicing.

    FEATURES
  • Includes a z-axis calibration unit
  • Z-axis blade adjust minimizer
  • Blade holder angle to user requirement
  • Set start and stop position from blade travel.
  • Vibration speeds from 50 to 120 Hz
  • Amplitudes from 0.5mm to 2.5mm
  • Controlled blade advance at 10microns per sec
  • Manual or automatic operation
  • "Auto" programming by storage of the first slicing
  • Ice water bath easily removed for cleaning
  • Optional LED light and scope for clear observation

Specifications

Section thickness step size: 0.001 mm
Bath table rise & fall speed: 1.0 mm/sec maximum
Maximum (vertical) travel of bath table: 19 mm
Cutting head advance speed   Minimum: -4.0 mm/sec (-1.00 during slicing)
Maximum: +4.0 mm/sec (+1.00 during slicing)  
Cutting head retraction speed: 4.0 mm/sec
Maximum travel of cutting head: 40 mm
Blade oscillation frequency Minimum: 50 Hz
Maximum: 120 Hz (amplitude dependent)
Frequency step size: 5 Hz
Blade oscillation amplitude   Minimum: 0.5 mm (nominal)
Maximum: 2.5 mm (nominal)
Amplitude step size: 0.25 mm (nominal)
Power requirements (Selectable): 115VAC 60Hz, 230VAC 50Hz
Power rating: 100W
Fuse rating (115V): T2A 250VAC
Fuse rating (230V): T2A 250VAC
Light source: 100-240Vac 3W
Dimensions: 410mm Width x 400mm Depth x 270mm Height (excluding light source and microscope)
Weight: 33Kg (excluding microscope)
Boxed shipping weight: 60Kg (excluding microscope)

 

Accessories

7000-60-1

7000-60-1

Crate for 7000 Series Slicer

View details...

7000-1-3

7000-1-3

Integrally Mounted Magnifying Glass for 7000smz tissue slicer

View details...


Choose Quantity
7550-1-C

7550-1-C

Specialized Ceramic blades for Vibrating Microtomes. These blades are honed with a sing...

View details...


Choose Quantity
7550-1-SS

7550-1-SS

Stainless Steel Blades - 50 pack;Recently redesigned following customer feedback and ap...

View details...

7470 Tissue Slice Recovery Chamber

7470 Tissue Slice Recovery Chamber

Tissue Slice Recovery Chamber

View details...

7610A Temperature Controlled Standard Tissue Bath

7610A Temperature Controlled Standard Tissue Bath

Temperature Controlled Standard Tissue Bath

View details...

7611A Temperature Controlled Warming Tissue Bath Model

7611A Temperature Controlled Warming Tissue Bath Model

Temperature Controlled Warming Tissue Bath Model

View details...

Citations

Preparation of viable adult ventricular myocardial slices from large and small mammals
Samuel A Watson, Martina Scigliano, Ifigeneia Bardi, Raimondo Ascione, Cesare M Terracciano & Filippo Perbellini

Nature Protocols volume 12, pages 2623-2639 (2017) 

Free-of-Acrylamide SDS-based Tissue Clearing (FASTClear) for three dimensional visualization of myocardial tissue
Filippo Perbellini, Alan K. L. Liu, Samuel A. Watson, Ifigeneia Bardi, Stephen M. Rothery & Cesare M. Terracciano

Scientific Reports 7, Article number: 5188 (2017) 
 

RelatedItems

5100mz

5100mz

The standard 5100mz shares the User interface with the premium 7000smz-2, placing a ...

View details...


Choose Quantity
7550-1-C

7550-1-C

Specialized Ceramic blades for Vibrating Microtomes. These blades are honed with a sing...

View details...


Choose Quantity
7550-1-SS

7550-1-SS

Stainless Steel Blades - 50 pack;Recently redesigned following customer feedback and ap...

View details...

7610A Temperature Controlled Standard Tissue Bath

7610A Temperature Controlled Standard Tissue Bath

Temperature Controlled Standard Tissue Bath

View details...

7611A Temperature Controlled Warming Tissue Bath Model

7611A Temperature Controlled Warming Tissue Bath Model

Temperature Controlled Warming Tissue Bath Model

View details...

Our Clients Include:

GlaxoSmithKline
University College London
Novartis
Imperial College
University of Cambridge
University of Oxford

Keep in Touch

We promise NEVER to share your details with anyone. You can opt out at any time.